All products of Wuxi ZOZEN Boiler Co., Ltd. are 100% factory inspected to ensure high quality. We have manufactured 6 series of 400 types of boilers, including steam boilers, hot water boilers, power station boilers, fire tube boilers, water tube boilers, CFB boilers, chain grate boilers, biomass fuel boilers, gas and oil boilers and waste heat Recovery boilers, products are widely used in manufacturing (chemical, coking, paper, food processing, etc.), thermal power plants, building materials and other industries.
Recommend Products
Related Cases

Boiler Formulas | Johnston Boil
Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP =
Get a Quote
Sizing a Steam Boiler | U.S. Boiler Compa
Dec 05, 2017· A better choice would be 1-1/2” or 2” of pipe insulation. An un-insulated steam main is equal to a radiator and must be calculated and added to the above calculation. When operating a steam boiler without insulation on the main steam pipes in the basement, you’ll need a larger boiler, incurring higher operating costs.
Get a Quote
horizontal boiler Agent design calculatio
Home / horizontal boiler Agent design calculations. Recovery of Water from Boiler Flue Gas Using . 2019-10-21 · @article{osti_1084027, title = {Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers}, author = {Levy, Edward and Bilirgen, Harun and DuPont, John}, abstractNote = {Most of the water used in a thermoelectric power ...
Get a Quote
Steam Consumption of Heat Exchangers | Spirax Sar
Determine the design rating of a heating calorifier from actual measured conditions The design rating of a heating calorifier is unknown, but the steam load is measured at 227 kg/h when the outside temperature is 7 °C and the inside temperature is 19 °C, a difference of 12 °C.
Get a Quote
Steam Outlet Size Calculation : Boiler Calculator by .
Steam outlet size calculation shown below is the recommended size of a steam outlet valve, however, the actual size of a steam outlet valve must be taken above and nearest to the recommended calculated size. Steam outlet size of a boiler is dependent on 2 important design criteria mentioned below:- Required Boiler Capacity or steam … Calculator: Steam Outlet Size Calculation Read More »
Get a Quote
Boiler BTU Calculator - SupplyHouse.c
Boiler BTU Calculator - Boiler Sizing Calculator - Boiler Sizing - Boiler BTU Calculator. Free shipping on orders over $99 We only ship within the United States. Your Zip: × Zip Code ...
Get a Quote
QUIZ: Boiler Water Treatment Chemical Guidelines — Part
Boiler Water Treatment Chemical Guidelines—Part Il continued Because of the associated corrosion problems, chelants are not the preferred treatment choice. However, if the system dictates the use of chelating agents, it can feed under "starvation" conditions, i.e., no free residual in the boiler. Based on the trace level of hardness in the boiler
Get a Quote
BOILER FEED & PUMP SIZING - Cleaver-Broo
Tangent Tube Furnace Design Also Available. 9. CONDENSATE IS LIQUID GOLD! A finite resource 10. TYPICAL . STEAM SYSTEM. T. T. T. T. T. Legend. ... STEAM BOILER PUMP APPLICATIONS AND TYPES Boiler feed pumps ... BASE FLOW RATE CALCULATION Base flow = Boiler maximum capacity horsepower X 0.069 X C • C = 1.5 for On/Off intermittent operation ...
Get a Quote
Calculating Boiler Chemical Requirements – Water .
Jun 26, 2017· The supplemental alkalinity requirement is, therefore, 20 ppm minus 15 ppm = 5 ppm required as calcium carbonate. Dividing 5 ppm by 50 (equivalent weight of calcium carbonate) gives 0.10 epm caustic soda (as 100% active), or 0.20 epm as 50% active.
Get a Quote
Heat Recovery Steam Generators (HRSGs), Part 3: Predicting .
Then under different gas inlet conditions, the (U.S.) design values are corrected for gas analysis, temperature and gas flow [see my book "Waste Heat Boiler Deskbook" for equations.] Then the actual duty transferred at each section is obtained using the equation (U.S.) corrected × D T. Gas/steam temperature profiles, duty and steam generation ...
Get a Quote
Johnston Boiler Company Boiler Glossary - Steam & Combusti
Nov 03, 2006· Steam Boilers & Appurtenances, Combustion & Instrumentation Controls, Deaerators, Exhaust Systems, Heat Exchangers, Heat Pipes, Industrial Pumps, Water Heaters, Water Softeners, Boiler Seminars, Services & Parts. 3 Common Boiler Formulas BOILER HORSE POWER What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi?
Get a Quote
Download boiler in excel simulation - ZachariahBatts's bl
Jul 05, 2012· boiler in excel simulation energy balance and boiler efficiency calculation (as per ASME PTC 4 code) using hands on excel based exercise. Using simulation tool, they would also be familiar with, such as Microsoft Excel , which will allow further analysis. An animated mimic diagram illustrates the operation of the steam boiler simulation, which.
Get a Quote
Steam Calculators: Deaerator Calculat
Mar 17, 2015· The inlet mass flows are determine based on an energy and mass flow balance: Minimum Inlet Energy Flow = Inlet Water Specific Enthalpy * Total DA Mass Flow. Additional Energy Flow Needed = Total Outlet Energy Flow - Minimum Inlet Energy Flow.
Get a Quote
Proper sizing of Boiler Feedwater Syst
One boiler horsepower = 34.5 lbs/hr of steam (or water) from and at 212o F. We also know that one-gallon of water weighs 8.37 lbs. To calculate the storage tank needed use the following formula: BHP X 34.5 ÷ 8.337 lbs ÷ 60 min. X 10 = minimum useable capacity in gallons. For example, if you have a 500 HP boiler the calculation will be as ...
Get a Quote
Boiler Water Treatment Chemicals, Feed, and Control .
Boiler Water Treatment Chemicals, Feed, and Control - Perhaps It Is More Complicated Than We Thought - Dave Christophersen CROWN Solutions, Inc. September 15, 2006 Chemicals used to treat steam boiler systems are applied based upon the demand and mode of reaction of each chemical used.
Get a Quote
Boiler design-calculation 3 - SlideSha
Mar 28, 2018· Lothers = convection radiation loss + ash sensitive loss + <fan credit> + unaccounted loss 7.3 Mass balance on the basis of higher heating value of coal, HHV The mass balance specifies important items such as the division of fuel ash and spent …
Get a Quote
Thermodynamic Design of a FireTube Steam Boil
engineering design projects, simulate engineering teamwork and collaboration, and exercise writing technical scientific documents. This document will introduce, derive and defend calculations for: I. Dimensions of steam boiler body and furnace. II. Diameter and length of steam boiler pipes. III.
Get a Quote
Download Free Heating Boilers Excel Sheet Calculat
Dec 19, 2017· H eating boiler calculation excel sheets: Boiler calculations Excel Sheet [] Heating capacity and boiler calculations PDF [] These excel sheets determine the amount of fuel energy required to produce steam with specified properties at a given flow rate using general boiler …
Get a Quote
(PDF) DESIGN AND FABRICATION OF PRESSING STEAM BOIL
Direct method: Direct method of boiler efficiency test is more usable or m ore common boiler efficiency =Q* (Hg -. Hf)/q*GCV *100 Q =T otal steam flow, Hg= Enthalpy of saturated steam in k c al ...
Get a Quote
Steam quality and drum sizing - Boiler and Pressure Vessel .
Jun 11, 2004· A certain area of water surface is required in a boiler from which to release the steam at an acceptable velocity with minimal carryover. I am looking for design standards or calculation methods for determining steam drum diameters and lenghts to ensure that the area of the normal water level would be acceptable for a given steam load.
Get a Quote
BLOWDOWN CALCULATION FOR BOILER - Altr
S = Amount of solids (ppm) B = Blow down (m3/ hr) C = Maximum permissible concentration of solid inside the boiler drum. B = E x S (m3/ hr.) C – S. % B = S C – S. This formula has been equally applied to control individual constituents in boiler. Blow down means, “lost heat”.
Get a Quote