All products of Wuxi ZOZEN Boiler Co., Ltd. are 100% factory inspected to ensure high quality. We have manufactured 6 series of 400 types of boilers, including steam boilers, hot water boilers, power station boilers, fire tube boilers, water tube boilers, CFB boilers, chain grate boilers, biomass fuel boilers, gas and oil boilers and waste heat Recovery boilers, products are widely used in manufacturing (chemical, coking, paper, food processing, etc.), thermal power plants, building materials and other industries.

Recommend Products

gas/oil fired boiler

1-20 t/h | 0.7-2 Mpa

biomass steam boiler

2 – 20 t/h | 1 - 2.5 Mpa

thermal oil heater

700 - 14000 KW

CFB steam boiler

35 - 75 t/h | 1.25 - 5.3 Mpa

Related Cases

Coal-fired Boiler

6tph SZL series boiler project

Location: Bangladesh

Equipment: SZL6-1.25-AII

Coal-fired Boiler

4 tph DZL series boiler Project

Location: Central Java, Indonesia

Equipment: DZL4-1.25-AII

Biomass-fired Boiler

20 tph SZL series boiler project

Location: Thailand

Equipment: SZL20-2.45-M

steam calculators: boiler calculat

Steam Calculators: Boiler Calculat

The Specific Enthalpy is then multiplied by the Mass Flow to get the Energy Flow: Pressure = 417.7 psig; Temperature = 343.6 °C [Steam Property Calculator] => Specific Enthalpy = 1,333.4 btu/lbm; Steam Energy Flow = Specific Enthalpy * Mass Flow [ Steam Energy Flow = 33,200 = …

Get a Quote
description of 150-500kw boiler and functions | cstfi

Description of 150-500kW boiler and functions | CSTfi

150 kW – 180 kW – 199 kW – 220 kW – 250 kW 300 kW – 350 kW – 400 kW – 450 kW – 499 kW – 500 kW The boilers are predominantly supplied with a so-called central fuel extinguishing device which automatically feeds in the fuel from the central warehouse to the boiler’s intermediate container (USZI).

Get a Quote
how to convert steam to btu | scienci

How to Convert Steam to BTU | Scienci

Mar 13, 2018· For the low-pressure steam typically used in heating systems, that ratio is 1,194 BTUs for every pound of steam the system provides. If your boiler supplies 400 pounds of steam per hour, for example, you would multiply 400 pounds by 1,194 to arrive at a figure of 477,600 BTUs.

Get a Quote
boiler feed water flow rate requirements chart | nalco p

Boiler Feed Water Flow Rate Requirements Chart | Nalco P

Dec 29, 2006· This chart relates boiler horse power to the flow rate in gallons per minute and pounds per hour. In this case, we need a demineralizer or softener rated for a maximum flow rate of 28 gpm. It will be less depending upon how much condensate is returned. The next part of this question is what water quality is needed for the application.

Get a Quote
steam flow rate versus kw rating - engineering toolb

Steam Flow Rate versus kW Rating - Engineering ToolB

Steam flow rate when kW rating is known can be calculated as. m s = 3600 P / h e (1). where. m s = steam flow rate (kg/h). P = load in kW (kW) h e = specific enthalpy of evaporation of steam …

Get a Quote
boiler - binder energietechnik gm

Boiler - BINDER Energietechnik Gm

• preheats the return flow via a duct along the boiler jacket. 5 ... 11 Moving Grate Boiler from >150 kW ... Saturated steam boiler Available from nominal capacity of 200 kW upwards, combinable with all BINDER combustion systems, for the production of saturated steam. Working pressure up to 22 barG available, higher pressure on demand.

Get a Quote
how to calculate the fuel consumption of the boiler-zozen boil

How to Calculate the Fuel Consumption of the Boiler-Zozen Boil

The 10 ton gas fired boiler has an output of 10 tons per hour, which is also the capacity of the boiler. To calculate the gas consumption of a natural gas boiler, you need to know the heat resistance of the heating surface of the natural gas boiler, the heat value of the natural gas boiler, and the efficiency of a 10-ton boiler.

Get a Quote
how much steam does 2500 hp boiler produce – industrial .

how much steam does 2500 hp boiler produce – Industrial .

Boiler HP x 34.5 Boiler HP x.069 Boiler HP x 33.4 Boiler HP x 139 BTU/Hour Output ч 240 EDR/1000 x 0.5 Lbs of Steam /Hr ч 500 = Lbs. of Steam per Hour . 150 HP Boiler Models – Steam & Hot Water – Power Mechanical At 150 HP, you get maximum steam or hot water capacity with a minimally sized footprint, a low overall height for plants with ...

Get a Quote
what size of boiler do i need for my home? | viessma

What size of boiler do I need for my home? | Viessma

Boiler size actually refers to the output in kilowatts (kW), not the physical dimensions. A kilowatt is a unit that is used to measure how much energy is output by the boiler in the form of heat. Generally speaking, the more heat and hot water you require, the higher the output you will need although other factors also play a part in choosing ...

Get a Quote
common steam boiler problems & how to troubleshoot repai

Common Steam Boiler Problems & How to Troubleshoot Repai

How a Steam Boiler Works. Steam boilers use a contained heat system to generate steam. The steam travels through pipes in the building’s walls where they emerge at radiators in heating systems. The radiators warm from the steam’s heat. As the steam gives off its heat, it condenses back to liquid water and returns to the tank.

Get a Quote
general engineering data - complete boiler room solutio

General Engineering Data - Complete Boiler Room Solutio

Select the line corresponding to the required flow, and the column corresponding to the nominal pipe size. The intersection will give the pressure drop in psi per 100 feet of equivalent pipe length. For example, a typical No. 2 fuel oil has a viscosity 40 SSU. A 500 hp boiler …

Get a Quote
combined heat and power technology fact sheets series .

Combined Heat and Power Technology Fact Sheets Series .

500 kW steam turbine utiliz-ing a natural gas fired boiler will have estimated NOx emissions in the range of 26-81 ppm (at 3% oxygen). A larger 15,000 kW CHP steam turbine integrated with a natural gas boiler will have estimated NOx emis-sions in the range of 81-226 ppm (at 3% oxygen). This 15,000 kW steam turbine, if integrated with a coal fired

Get a Quote
circulating water requirements in a thermal power plant .

Circulating Water Requirements in a Thermal Power Plant .

Based on a simple heat balance, the requirement will be almost 65 to 70 times the steam flow entering the Turbine. A 600 MW thermal power plant uses around 1800 tons per hour of steam from the boiler. This means the circulating water requirement in tropical …

Get a Quote
boiler fuel consumption calculation--z

Boiler Fuel Consumption Calculation--Z

Boiler Fuel Consumption Calculation 2017-07-04 15:07:05. Many customers ask us boiler price, the cost of the boiler and how to calculate boiler fuel consumption when they want to purchase a boiler.. For the calculation of boiler fuel consumption, firstly, determine the specifications and boiler steam production, and the actual enthalpy increment of the boiler is calculated from the steam ...

Get a Quote
steam mass flow rate - an overview | sciencedirect topi

Steam Mass Flow Rate - an overview | ScienceDirect Topi

The air flow rate to CASU producing the maximum hydrogen generation rate per unit steam mass flow rate rises as the steam mass flow rate upsurges, excluding the steam mass flow rates of 1 kg/s to 20 kg/s. When the content of carbon in coal drops, an inferior air mass flow rate to the CASU is required to yield the maximum hydrogen generation rate.

Get a Quote
catalog of chp technologies, section 4. technology .

Catalog of CHP Technologies, Section 4. Technology .

Steam turbines differ from reciprocating engines, internal combustion engines, and gas turbines in that the fuel is burned in a piece of equipment, the boiler, which is separate from the power generation equipment. The energy is transferred from the boiler to the steam turbine generator by an intermediate medium, typically steam under pressure.

Get a Quote
500kw biomass boiler - sustainable ener

500kW Biomass Boiler - Sustainable Ener

The biomass boiler solution comprises a 500kW wood pellet boiler with 50m³ pellet silo and 30,000litres thermal storage. Back up heat is provided by 2.3MW auxiliary gas boilers; the system design includes full integration of the biomass and gas boilers, aided by a comprehensive control and monitoring system.

Get a Quote
biomass equipment options for steam and power .

Biomass Equipment Options for Steam and Power .

One of the goals is to reduce fossil fuel use in our steam and power plants. Biomass-fueled boilers or gasifiers can be used to replace fuel oil or natural gas as one method to accomplish this goal. For a 100,000 pound per hour steam boiler, operating costs can be reduced by more than 50 percent depending on the cost of fuel.

Get a Quote
boiler ratings - spirax sarco | first for steam solutio

Boiler Ratings - Spirax Sarco | First for Steam Solutio

Equation 3.5.2 can then be used to calculate the steam output: Example 3.5.2. A boiler is rated at 3 000 kW (kJ/s) and operates at 10 bar g with a feedwater temperature of 50°C. How much steam can be generated? Where, from using the tables on the Spirax Sarco website:

Get a Quote
hurst boiler | boiler models| plan views | spec shee

Hurst Boiler | Boiler Models| Plan Views | Spec Shee

Hurst Boiler, Inc. is the leading manufacturer of gas, oil, wood, coal, solid fuel, solid waste, biomass and hybrid fuel-fired steam and hot water boilers. Hurst Product Collection Brochure 4.164 MB

Get a Quote
how much steam is required to generate 1mw of electricity .

How much steam is required to generate 1MW of electricity .

Sep 01, 2016· The amount of steam required to produce 1 MW of electric power depends upon so many factor, the most important being, the steam temperature and pressure at the exit of Boiler, the isentropic efficiency of Turbine, the availability of reheat, the c...